T1 - Evaluation of Artifacts Associated with Macular Spectral-Domain Optical Coherence Tomography
AU - Han, Ian C.
AU - Jaffe, Glenn J.
N1 - Funding Information:
Supported by a Medical Student Research Training Fellowship from the Howard Hughes Medical Institute , Chevy Chase, Maryland, and by the National Eye Institute , Bethesda Maryland (Core Grant no.: P30EY05722 ).
Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2010/6
Y1 - 2010/6
N2 - Purpose: To characterize the types and frequencies of image artifacts associated with macular scanning using 2 common spectral-domain optical coherence tomography (SD OCT) instruments and to evaluate the impact of artifacts on foveal thickness measurements. Design: Retrospective, observational chart review. Participants: For the Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA), scans of 98 eyes from 58 patients were included in the study. For the Spectralis HRA+OCT (Heidelberg Engineering, Heidelberg, Germany), scans of 88 eyes from 54 patients were included. Methods: Macular volume scans of healthy and diseased eyes were evaluated systematically for image artifacts within each scan overall and within the center 1-mm area. The frequency of each artifact type was compared for scans stratified by diagnosis category. Artifacts in the center 1-mm area were graded for severity and were corrected manually using each instrument's software. Artifacts that resulted in errors of more than 50 μm or more than 10% of retinal thickness or that caused a misdiagnosis of macular edema or retinal thinning were defined as clinically significant and were analyzed further. Main Outcome Measures: Overall frequency of image artifacts by artifact type, relative frequency of artifacts in scans stratified by posterior segment disease diagnosis, and retinal thickness measurements of the center 1-mm subfield before and after artifact corrections. Results: For Cirrus, 84.7% of scans had artifacts and 32.7% had at least 1 artifact in the center 1-mm area of the scan. For Spectralis, 90.9% of scans had at least 1 artifact, and 37.5% had at least 1 artifact in the center 1-mm area. Certain artifact types were observed more frequently with specific disease states. Clinically significant artifacts involving the center 1-mm area were seen in 5.1% of Cirrus and 8.0% of Spectralis scans. Conclusions: Image artifacts in SD OCT volume scanning are common and frequently involve segmentation errors. Artifacts are relatively less common in the center 1-mm area of scans, but may affect retinal thickness measurements in a clinically significant manner. Careful review of scans for artifacts is important when using SD OCT images and retinal thickness measurements in patient care or clinical trials. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article.
AB - Purpose: To characterize the types and frequencies of image artifacts associated with macular scanning using 2 common spectral-domain optical coherence tomography (SD OCT) instruments and to evaluate the impact of artifacts on foveal thickness measurements. Design: Retrospective, observational chart review. Participants: For the Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA), scans of 98 eyes from 58 patients were included in the study. For the Spectralis HRA+OCT (Heidelberg Engineering, Heidelberg, Germany), scans of 88 eyes from 54 patients were included. Methods: Macular volume scans of healthy and diseased eyes were evaluated systematically for image artifacts within each scan overall and within the center 1-mm area. The frequency of each artifact type was compared for scans stratified by diagnosis category. Artifacts in the center 1-mm area were graded for severity and were corrected manually using each instrument's software. Artifacts that resulted in errors of more than 50 μm or more than 10% of retinal thickness or that caused a misdiagnosis of macular edema or retinal thinning were defined as clinically significant and were analyzed further. Main Outcome Measures: Overall frequency of image artifacts by artifact type, relative frequency of artifacts in scans stratified by posterior segment disease diagnosis, and retinal thickness measurements of the center 1-mm subfield before and after artifact corrections. Results: For Cirrus, 84.7% of scans had artifacts and 32.7% had at least 1 artifact in the center 1-mm area of the scan. For Spectralis, 90.9% of scans had at least 1 artifact, and 37.5% had at least 1 artifact in the center 1-mm area. Certain artifact types were observed more frequently with specific disease states. Clinically significant artifacts involving the center 1-mm area were seen in 5.1% of Cirrus and 8.0% of Spectralis scans. Conclusions: Image artifacts in SD OCT volume scanning are common and frequently involve segmentation errors. Artifacts are relatively less common in the center 1-mm area of scans, but may affect retinal thickness measurements in a clinically significant manner. Careful review of scans for artifacts is important when using SD OCT images and retinal thickness measurements in patient care or clinical trials. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article.
UR - http://www.scopus.com/inward/record.url?scp=77952892012&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77952892012&partnerID=8YFLogxK
U2 - 10.1016/j.ophtha.2009.10.029
DO - 10.1016/j.ophtha.2009.10.029
M3 - Article
C2 - 20171740
AN - SCOPUS:77952892012
SN - 0161-6420
VL - 117
SP - 1177-1189.e4
JO - Ophthalmology
JF - Ophthalmology
IS - 6
ER -