T1 - Evaluation of 3D image registration as applied to MR-guided thermal treatment of liver cancer
AU - Wilson, David L.
AU - Carrillo, Andres
AU - Zheng, Lan
AU - Genc, Ahmet
AU - Duerk, Jeffrey L.
AU - Lewin, Jonathan S.
PY - 1998/1
Y1 - 1998/1
N2 - There are many potential applications of three-dimensional (3D) image registration in MR-guided radiofrequency (RF) thermal ablation of tumors. For example, after registration of image volumes obtained before and after thermal ablation, a variety of quantitative and visual assessments of therapy were performed. For liver tumors, the accuracy of rigid body, manual registration on 19 pairs of image volumes was evaluated, almost all of which were obtained during thermal treatment sessions. Registration error was estimated as a distance between anatomical landmarks, including both internal vascular structures as well as the surface of the liver. Over all image pairs and throughout a large portion of the liver, the registration error was 3.1 mm (mean + 1 SD). From the bottom to the top of the liver, error increased on the order of 13%, probably because of liver motion and deformation resulting from respiration. Although probably insufficient for blind guidance of therapy, registration accuracy was undoubtedly sufficient for interesting applications in the planning, assessment, and optimization of interventional MR-guided thermal treatment of liver tumors.
AB - There are many potential applications of three-dimensional (3D) image registration in MR-guided radiofrequency (RF) thermal ablation of tumors. For example, after registration of image volumes obtained before and after thermal ablation, a variety of quantitative and visual assessments of therapy were performed. For liver tumors, the accuracy of rigid body, manual registration on 19 pairs of image volumes was evaluated, almost all of which were obtained during thermal treatment sessions. Registration error was estimated as a distance between anatomical landmarks, including both internal vascular structures as well as the surface of the liver. Over all image pairs and throughout a large portion of the liver, the registration error was 3.1 mm (mean + 1 SD). From the bottom to the top of the liver, error increased on the order of 13%, probably because of liver motion and deformation resulting from respiration. Although probably insufficient for blind guidance of therapy, registration accuracy was undoubtedly sufficient for interesting applications in the planning, assessment, and optimization of interventional MR-guided thermal treatment of liver tumors.
KW - 3D image registration
KW - Cancer therapy
KW - Interventional MRI
KW - Medical Image analysis
KW - RF thermal ablation
UR - http://www.scopus.com/inward/record.url?scp=0031909657&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031909657&partnerID=8YFLogxK
U2 - 10.1002/jmri.1880080117
DO - 10.1002/jmri.1880080117
M3 - Article
C2 - 9500264
AN - SCOPUS:0031909657
SN - 1053-1807
VL - 8
SP - 77
EP - 84
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 1
ER -