Energy drink-induced near-fatal ventricular arrhythmia prevented by an intracardiac defibrillator decades after operative "repair" of tetralogy of fallot

Alexandra E. Ward, Steven E. Lipshultz, Stacy D. Fisher

Research output: Contribution to journalArticlepeer-review

Abstract

We describe a 45-year old man who experienced a potentially fatal arrhythmia after consumption of multiple energy drinks. At 5 years old, he underwent "repair" of tetralogy of Fallot using a patch in the right ventricular outflow tract, and at age 40 had an automatic implantable cardiac defibrillator (AICD) placed. His first AICD shock occurred within 30 minutes after he finished the third energy drink and was preceded by feelings of lightheadedness and severe dizziness. Without the AICD, he likely would have died. The risk of consuming energy drinks in those with underlying structural heart disease and the general population should be determined. Warning labels should be required to inform consumers of the risks posed by these drinks and of appropriate limits for consumption.

Original languageEnglish (US)
Pages (from-to)1124-1125
Number of pages2
JournalAmerican Journal of Cardiology
Volume114
Issue number7
DOIs
StatePublished - Oct 1 2014
Externally publishedYes

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Energy drink-induced near-fatal ventricular arrhythmia prevented by an intracardiac defibrillator decades after operative "repair" of tetralogy of fallot'. Together they form a unique fingerprint.

Cite this