TY - JOUR
T1 - Endothelial lamellar keratoplasty using an artificial anterior chamber and a microkeratome
AU - Behrens, Ashley
AU - Ellis, Kenneth
AU - Li, Li
AU - Sweet, Paula M.
AU - Chuck, Roy S.
N1 - Copyright:
Copyright 2008 Elsevier B.V., All rights reserved.
PY - 2003/4/1
Y1 - 2003/4/1
N2 - Objective: To compare postoperative astigmatic change and graft stability using 2 different donor button diameters in endothelial lamellar keratoplasty to treat corneal endothelial failure. Methods: A 200-μm-thick corneal flap keratectomy was performed in human donor corneoscleral rims (n = 20; 10 donors and 10 recipients) using an artificial anterior chamber and a manual microkeratome (ALTK System; Moria USA, Doylestown, Pa). After flap reflection, stromal bed trephination was performed to obtain a disc consisting of posterior stroma, Descemet membrane, and endothelium. Host beds of 7.0 mm and 7.25-mm (n = 5) or 7.50-mm (n = 5) donor buttons were obtained using a freehand trephine. The graft was secured with 8 interrupted sutures (10-0 nylon) in the stromal bed. The flap was sutured with 3 interrupted sutures. Transplanted corneas were submitted to increasing intrachamber pressures to detect graft stability, and preoperative and postoperative videokeratographic data were recorded to assess astigmatic change. Results: The mean (SD) postoperative astigmatic change was 1.14 (3.17) diopters (D) in the 7.25-mm donor button group and 2.27 (1.77) D in the 7.50-mm donor button group (P = .69). Mean (SD) resisted pressures of 75.4 (44.81) mm Hg and 100.4 (46.86) mm Hg were observed in the 7.25-mm and 7.50-mm groups, respectively (P = .54). Conclusion: Both donor button sizes exhibited similar graft stability and astigmatic postoperative change in this experimental model. Clinical Relevance: As endothelial lamellar keratoplasty becomes further developed as a clinical alternative to penetrating keratoplasty, this laboratory model system should be useful in evaluating different mechanical factors that contribute to graft success.
AB - Objective: To compare postoperative astigmatic change and graft stability using 2 different donor button diameters in endothelial lamellar keratoplasty to treat corneal endothelial failure. Methods: A 200-μm-thick corneal flap keratectomy was performed in human donor corneoscleral rims (n = 20; 10 donors and 10 recipients) using an artificial anterior chamber and a manual microkeratome (ALTK System; Moria USA, Doylestown, Pa). After flap reflection, stromal bed trephination was performed to obtain a disc consisting of posterior stroma, Descemet membrane, and endothelium. Host beds of 7.0 mm and 7.25-mm (n = 5) or 7.50-mm (n = 5) donor buttons were obtained using a freehand trephine. The graft was secured with 8 interrupted sutures (10-0 nylon) in the stromal bed. The flap was sutured with 3 interrupted sutures. Transplanted corneas were submitted to increasing intrachamber pressures to detect graft stability, and preoperative and postoperative videokeratographic data were recorded to assess astigmatic change. Results: The mean (SD) postoperative astigmatic change was 1.14 (3.17) diopters (D) in the 7.25-mm donor button group and 2.27 (1.77) D in the 7.50-mm donor button group (P = .69). Mean (SD) resisted pressures of 75.4 (44.81) mm Hg and 100.4 (46.86) mm Hg were observed in the 7.25-mm and 7.50-mm groups, respectively (P = .54). Conclusion: Both donor button sizes exhibited similar graft stability and astigmatic postoperative change in this experimental model. Clinical Relevance: As endothelial lamellar keratoplasty becomes further developed as a clinical alternative to penetrating keratoplasty, this laboratory model system should be useful in evaluating different mechanical factors that contribute to graft success.
UR - http://www.scopus.com/inward/record.url?scp=0345118153&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0345118153&partnerID=8YFLogxK
U2 - 10.1001/archopht.121.4.503
DO - 10.1001/archopht.121.4.503
M3 - Article
C2 - 12695247
AN - SCOPUS:0345118153
SN - 0003-9950
VL - 121
SP - 503
EP - 508
JO - Archives of ophthalmology
JF - Archives of ophthalmology
IS - 4
ER -