TY - JOUR
T1 - Effects of Glucagon-Like Peptide-1 Receptor Agonists on Atrial Fibrillation Recurrence After Catheter Ablation
AU - Satti, Danish Iltaf
AU - Karius, Alexander
AU - Chan, Jeffrey Shi Kai
AU - Isakadze, Nino
AU - Yadav, Ritu
AU - Garg, Keva
AU - Aronis, Konstantinos N.
AU - Marine, Joseph E.
AU - Berger, Ronald
AU - Calkins, Hugh
AU - Spragg, David
N1 - Publisher Copyright:
© 2024 American College of Cardiology Foundation
PY - 2024/8
Y1 - 2024/8
N2 - Background: Relationship between glucagon-like peptide-1 receptor agonist (GLP-1 RA) use prior to atrial fibrillation (AF) ablation and subsequent AF recurrence is not well-understood. Objectives: This study investigated the effects of GLP-1 RA use within 1 year before ablation and its association with AF recurrence and associated outcomes. Methods: The TriNetX research database was used to identify patients aged ≥18 years undergoing AF ablation (2014-2023). Patients were categorized into 2 groups, and propensity score matching (1:1) between preablation GLP-1 RA users and nonusers was performed based on demographics, comorbidities, body mass index, laboratory tests, AF subtype, and medications. Primary outcome was composite of cardioversion, new antiarrhythmic drug therapy, or repeat AF ablation after a 3-month blanking period following the index ablation. Additional outcomes included ischemic stroke, all-cause hospitalization, and mortality during 12-month follow-up period. Results: After 1:1 propensity score matching, the study cohort comprised 1,625 GLP-1 RA users and 1,625 matched GLP-1 RA nonusers. Preablation GLP-1 RA therapy was not associated with a lower risk of cardioversion, new AAD therapy, and repeat AF ablation after the index procedure (HR: 1.04 [95% CI: 0.92-1.19]; log-rank P = 0.51). Furthermore, the risk of ischemic stroke, all-cause hospitalization, and mortality during the 12-month follow-up period did not differ between the 2 groups. Conclusions: These findings suggest that preprocedural use of GLP-1 RAs is not associated with a reduced risk of AF recurrence or associated adverse outcomes following ablation, and underscore the need for future research to determine whether these agents improve outcome in AF patients.
AB - Background: Relationship between glucagon-like peptide-1 receptor agonist (GLP-1 RA) use prior to atrial fibrillation (AF) ablation and subsequent AF recurrence is not well-understood. Objectives: This study investigated the effects of GLP-1 RA use within 1 year before ablation and its association with AF recurrence and associated outcomes. Methods: The TriNetX research database was used to identify patients aged ≥18 years undergoing AF ablation (2014-2023). Patients were categorized into 2 groups, and propensity score matching (1:1) between preablation GLP-1 RA users and nonusers was performed based on demographics, comorbidities, body mass index, laboratory tests, AF subtype, and medications. Primary outcome was composite of cardioversion, new antiarrhythmic drug therapy, or repeat AF ablation after a 3-month blanking period following the index ablation. Additional outcomes included ischemic stroke, all-cause hospitalization, and mortality during 12-month follow-up period. Results: After 1:1 propensity score matching, the study cohort comprised 1,625 GLP-1 RA users and 1,625 matched GLP-1 RA nonusers. Preablation GLP-1 RA therapy was not associated with a lower risk of cardioversion, new AAD therapy, and repeat AF ablation after the index procedure (HR: 1.04 [95% CI: 0.92-1.19]; log-rank P = 0.51). Furthermore, the risk of ischemic stroke, all-cause hospitalization, and mortality during the 12-month follow-up period did not differ between the 2 groups. Conclusions: These findings suggest that preprocedural use of GLP-1 RAs is not associated with a reduced risk of AF recurrence or associated adverse outcomes following ablation, and underscore the need for future research to determine whether these agents improve outcome in AF patients.
KW - GLP-1 receptor agonists
KW - atrial fibrillation
KW - catheter ablation
UR - http://www.scopus.com/inward/record.url?scp=85195367566&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85195367566&partnerID=8YFLogxK
U2 - 10.1016/j.jacep.2024.03.031
DO - 10.1016/j.jacep.2024.03.031
M3 - Article
C2 - 38795099
AN - SCOPUS:85195367566
SN - 2405-500X
VL - 10
SP - 1848
EP - 1855
JO - JACC: Clinical Electrophysiology
JF - JACC: Clinical Electrophysiology
IS - 8
ER -