T1 - Design of a rate controlled indentor for In Vivo analysis of residual limb tissues
AU - Arvind, P.
AU - Pathak, B. E.
AU - Barbara Silver-Thorn, M.
PY - 1996/12/1
Y1 - 1996/12/1
N2 - A tissue tester was designed to enable rate controlled indentation of the soft tissues of the residual limbs of below-knee (BK) amputees. Thus viscoelastic phenomena such as pre-conditioning, hysteresis and stress relaxation could be assessed. The tissue tester accommodates indentor excursions of 0-30 mm, performs indentations at rates from 0-5 mm/s, measures reaction forces up to 44 N, and accommodates multiple loading/unloading cycles. The tissue tester is controlled via a notebook personal computer which makes the entire test system portable and amenable for use in a clinical or research environment The system output consists of force-displacement curves obtained during cyclic loading of the tissue at varying indentation rates at sites of clinical significance to BK prosthetic design. Indentation followed by force monitoring over a fixed time duration allows stress relaxation of the tissue to be assessed. The indentor positioning error (mean error less than 4.4%) is independent of indentor position and load, but dependent on indentation rate. Indentation rates are accurate to within 3% of the desired value and are independent of indentor position and load.
AB - A tissue tester was designed to enable rate controlled indentation of the soft tissues of the residual limbs of below-knee (BK) amputees. Thus viscoelastic phenomena such as pre-conditioning, hysteresis and stress relaxation could be assessed. The tissue tester accommodates indentor excursions of 0-30 mm, performs indentations at rates from 0-5 mm/s, measures reaction forces up to 44 N, and accommodates multiple loading/unloading cycles. The tissue tester is controlled via a notebook personal computer which makes the entire test system portable and amenable for use in a clinical or research environment The system output consists of force-displacement curves obtained during cyclic loading of the tissue at varying indentation rates at sites of clinical significance to BK prosthetic design. Indentation followed by force monitoring over a fixed time duration allows stress relaxation of the tissue to be assessed. The indentor positioning error (mean error less than 4.4%) is independent of indentor position and load, but dependent on indentation rate. Indentation rates are accurate to within 3% of the desired value and are independent of indentor position and load.
UR - http://www.scopus.com/inward/record.url?scp=0030405580&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030405580&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:0030405580
SN - 1071-6947
VL - 33
SP - 111
EP - 112
JO - American Society of Mechanical Engineers, Bioengineering Division (Publication) BED
JF - American Society of Mechanical Engineers, Bioengineering Division (Publication) BED
ER -