T1 - Coronary CT angiography
T2 - Variability of CT scanners and readers in measurement of plaque volume
AU - Symons, Rolf
AU - Morris, Justin Z.
AU - Wu, Colin O.
AU - Pourmorteza, Amir
AU - Ahlman, Mark A.
AU - Lima, João A.C.
AU - Chen, Marcus Y.
AU - Mallek, Marissa
AU - Sandfort, Veit
AU - Bluemke, David Alan
N1 - Publisher Copyright:
© RSNA, 2016.
PY - 2016/12
Y1 - 2016/12
N2 - Purpose: To determine reader and computed tomography (CT) scan variability for measurement of coronary plaque volume. Materials and Methods: This HIPAA-compliant study followed Standards for Reporting of Diagnostic Accuracy guidelines. Baseline coronary CT angiography was performed in 40 prospectively enrolled subjects (mean age, 67 years 6 6 [standard deviation]) with asymptomatic hyperlipidemia by using a 320-detector row scanner (Aquilion One Vision; Toshiba, Otawara, Japan). Twenty of these subjects underwent coronary CT angiography repeated on a separate day with the same CT scanner (Toshiba, group 1); 20 subjects underwent repeat CT performed with a different CT scanner (Somatom Force; Siemens, Forchheim, Germany [group 2]). Intraclass correlation coefficients (ICCs) and Bland- Altman analysis were used to assess interreader, intrareader, and interstudy reproducibility. Results: Baseline and repeat coronary CT angiography scans were acquired within 19 days 6 6. Interreader and intrareader agreement rates were high for total, calcified, and noncalcified plaques for both CT scanners (all ICCs 0.96) without bias. Scanner variability was 618.4% (coefficient of variation) with same-vendor follow-up. However, scanner variability increased to 629.9% with different-vendor follow-up. The sample size to detect a 5% change in noncalcified plaque volume with 90% power and an a error of .05 was 286 subjects for same-CT scanner follow-up and 753 subjects with different-vendor follow-up. Conclusion: State-of-the-art coronary CT angiography with same-vendor follow-up has good scan-rescan reproducibility, suggesting a role of coronary CT angiography in monitoring coronary artery plaque response to therapy. Differences between coronary CT angiography vendors resulted in lower scanrescan reproducibility.
AB - Purpose: To determine reader and computed tomography (CT) scan variability for measurement of coronary plaque volume. Materials and Methods: This HIPAA-compliant study followed Standards for Reporting of Diagnostic Accuracy guidelines. Baseline coronary CT angiography was performed in 40 prospectively enrolled subjects (mean age, 67 years 6 6 [standard deviation]) with asymptomatic hyperlipidemia by using a 320-detector row scanner (Aquilion One Vision; Toshiba, Otawara, Japan). Twenty of these subjects underwent coronary CT angiography repeated on a separate day with the same CT scanner (Toshiba, group 1); 20 subjects underwent repeat CT performed with a different CT scanner (Somatom Force; Siemens, Forchheim, Germany [group 2]). Intraclass correlation coefficients (ICCs) and Bland- Altman analysis were used to assess interreader, intrareader, and interstudy reproducibility. Results: Baseline and repeat coronary CT angiography scans were acquired within 19 days 6 6. Interreader and intrareader agreement rates were high for total, calcified, and noncalcified plaques for both CT scanners (all ICCs 0.96) without bias. Scanner variability was 618.4% (coefficient of variation) with same-vendor follow-up. However, scanner variability increased to 629.9% with different-vendor follow-up. The sample size to detect a 5% change in noncalcified plaque volume with 90% power and an a error of .05 was 286 subjects for same-CT scanner follow-up and 753 subjects with different-vendor follow-up. Conclusion: State-of-the-art coronary CT angiography with same-vendor follow-up has good scan-rescan reproducibility, suggesting a role of coronary CT angiography in monitoring coronary artery plaque response to therapy. Differences between coronary CT angiography vendors resulted in lower scanrescan reproducibility.
UR - http://www.scopus.com/inward/record.url?scp=84999666584&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84999666584&partnerID=8YFLogxK
U2 - 10.1148/radiol.2016161670
DO - 10.1148/radiol.2016161670
M3 - Article
C2 - 27636027
AN - SCOPUS:84999666584
SN - 0033-8419
VL - 281
SP - 737
EP - 748
JO - RADIOLOGY
JF - RADIOLOGY
IS - 3
ER -