TY - JOUR
T1 - Contemporary discrepancies of stenosis assessment by computed tomography and invasive coronary angiography
T2 - Analysis of the CORE320 international study
AU - Song, Young Bin
AU - Arbab-Zadeh, Armin
AU - Matheson, Matthew B.
AU - Ostovaneh, Mohammad R.
AU - Vavere, Andrea L.
AU - Dewey, Marc
AU - Rochitte, Carlos
AU - Niinuma, Hiroyuki
AU - Laham, Roger
AU - Schuijf, Joanne D.
AU - Cox, Christopher
AU - Brinker, Jeffrey
AU - Di Carli, Marcelo
AU - Lima, Joaõ A.C.
AU - Miller, Julie M.
N1 - Funding Information:
Dr Schuijf is an employee of Canon Medical Systems, Europe. Dr Arbab-Zadeh discloses his membership of the CORE320 (Coronary Artery Evaluation Using 320-Row Multidetector Computed Tomography Angiography and Myocardial Perfusion) steering committee. The CORE320 study was sponsored by Canon (formerly Toshiba) Medical Systems. Dr Lima discloses grant support from Canon Medical Systems. The other authors report no conflicts.
Publisher Copyright:
© 2019 American Heart Association, Inc.
PY - 2019/2/1
Y1 - 2019/2/1
N2 - Background: Ongoing advancements of coronary computed tomographic angiography (CTA) continue to challenge the role of invasive coronary angiography (ICA) as the gold standard for the evaluation of coronary artery disease (CAD). We sought to investigate the diagnostic accuracy of 320-slice CTA for detecting obstructive CAD in reference to ICA and nuclear myocardial perfusion imaging using single-photon emission computed tomography. Methods: For the CORE320 study (Coronary Artery Evaluation Using 320-Row Multidetector Computed Tomography Angiography and Myocardial Perfusion), 381 patients at 16 centers underwent CTA, nuclear myocardial perfusion imaging by single-photon emission computed tomography, and ICA for the evaluation of CAD. Imaging studies were analyzed in blinded core laboratories, and a stenosis of ≥50% by quantitative coronary angiography was considered obstructive, whereas a stress difference score of ≥1 indicated inducible myocardial ischemia. The area under the receiver operating characteristic curve was used to evaluate diagnostic accuracy. Results: Of 381 patients, 229 (60%) had obstructive CAD by quantitative coronary angiography. Diagnostic accuracy of CTA on a per-patient analysis revealed an area under the receiver operating characteristic curve of 0.90 (95% CI, 0.87-0.93). Per-vessel and per-segment analysis revealed lower area under the receiver operating characteristic curve of 0.87 (0.84-0.90) and 0.81 (0.78-0.83), respectively. Median radiation dose was lower for CTA versus ICA: 3.16 (interquartile range, 2.82-3.59) versus 11.97 (interquartile range, 7.60-17.8) mSv (P<0.001). Accuracy for identifying patients with inducible myocardial ischemia by SPECT-MPI was similar for CTA and ICA (area under the receiver operating characteristic curve, 0.68 versus 0.71 by quantitative coronary angiography and 0.68 by visual angiographic assessment; P>0.05). Furthermore, accuracy for identifying patients who subsequently underwent clinically driven coronary revascularization also was similar for CTA (0.76 [0.71-0.81]) and ICA (0.78 [0.74-0.83]; P=0.20). Conclusions: Contemporary CTA accurately identifies patients with obstructive CAD by ICA at lower radiation exposure; however, agreement is lower in vessel- A nd segment-level analyses. Both CTA and ICA perform similarly for predicting clinically driven revascularization and for detecting myocardial ischemia by myocardial perfusion imaging using single-photon emission computed tomography, suggesting that limitations by both CTA and ICA contribute to variability of stenosis quantification.
AB - Background: Ongoing advancements of coronary computed tomographic angiography (CTA) continue to challenge the role of invasive coronary angiography (ICA) as the gold standard for the evaluation of coronary artery disease (CAD). We sought to investigate the diagnostic accuracy of 320-slice CTA for detecting obstructive CAD in reference to ICA and nuclear myocardial perfusion imaging using single-photon emission computed tomography. Methods: For the CORE320 study (Coronary Artery Evaluation Using 320-Row Multidetector Computed Tomography Angiography and Myocardial Perfusion), 381 patients at 16 centers underwent CTA, nuclear myocardial perfusion imaging by single-photon emission computed tomography, and ICA for the evaluation of CAD. Imaging studies were analyzed in blinded core laboratories, and a stenosis of ≥50% by quantitative coronary angiography was considered obstructive, whereas a stress difference score of ≥1 indicated inducible myocardial ischemia. The area under the receiver operating characteristic curve was used to evaluate diagnostic accuracy. Results: Of 381 patients, 229 (60%) had obstructive CAD by quantitative coronary angiography. Diagnostic accuracy of CTA on a per-patient analysis revealed an area under the receiver operating characteristic curve of 0.90 (95% CI, 0.87-0.93). Per-vessel and per-segment analysis revealed lower area under the receiver operating characteristic curve of 0.87 (0.84-0.90) and 0.81 (0.78-0.83), respectively. Median radiation dose was lower for CTA versus ICA: 3.16 (interquartile range, 2.82-3.59) versus 11.97 (interquartile range, 7.60-17.8) mSv (P<0.001). Accuracy for identifying patients with inducible myocardial ischemia by SPECT-MPI was similar for CTA and ICA (area under the receiver operating characteristic curve, 0.68 versus 0.71 by quantitative coronary angiography and 0.68 by visual angiographic assessment; P>0.05). Furthermore, accuracy for identifying patients who subsequently underwent clinically driven coronary revascularization also was similar for CTA (0.76 [0.71-0.81]) and ICA (0.78 [0.74-0.83]; P=0.20). Conclusions: Contemporary CTA accurately identifies patients with obstructive CAD by ICA at lower radiation exposure; however, agreement is lower in vessel- A nd segment-level analyses. Both CTA and ICA perform similarly for predicting clinically driven revascularization and for detecting myocardial ischemia by myocardial perfusion imaging using single-photon emission computed tomography, suggesting that limitations by both CTA and ICA contribute to variability of stenosis quantification.
KW - ROC curve
KW - computed tomography angiography
KW - coronary angiography
KW - coronary artery disease
KW - humans
UR - http://www.scopus.com/inward/record.url?scp=85061564646&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85061564646&partnerID=8YFLogxK
U2 - 10.1161/CIRCIMAGING.118.007720
DO - 10.1161/CIRCIMAGING.118.007720
M3 - Article
C2 - 30764641
AN - SCOPUS:85061564646
SN - 1941-9651
VL - 12
JO - Circulation: Cardiovascular Imaging
JF - Circulation: Cardiovascular Imaging
IS - 2
M1 - e007720
ER -