title = "Cone-beam CT statistical reconstruction with a model for fluence modulation and electronic readout noise",
abstract = "Cone-beam CT (CBCT) systems with a flat-panel detector (FPD) have advanced in a variety of specialty diagnostic imaging scenarios, with fluence modulation and multiple-gain detectors playing important roles in extending dynamic range and improving image quality. We present a penalized weighted least-squares (PWLS) reconstruction approach with a noise model that includes the effects of fluence modulation and electronic readout noise, and we show preliminary results that tests the concept with a CBCT head scanner prototype. Methods: Statistical weights in PWLS were modified using a realistic noise model for the FPD that considers factors such as system blur and spatially varying electronic noise in multiple-gain readout detectors (PWLSe). A spatially varying gain term was then introduced in the calculation of statistical weights to account for the change in quantum noise due to fluence modulation (e.g. bowtie filter) (PWLS{\^a}-). The methods were tested in phantom experiments involving an elliptical phantom specially designed to stress dual-gain readout, and a water phantom and an anthropomorphic head phantom to quantify improvements in noise-resolution characteristics for the new PWLS methods (PWLSo-'' and PWLS{\^a}-, and combined PWLS{\^a}-e). The proposed methods were further tested using a high-quality, low-dose CBCT head scanner prototype in a clinical study involving patients with head injury. Results: Preliminary results show that the PWLSe method demonstrated superior noise-resolution tradeoffs compared to conventional PWLS, with variance reduced by ∼15-25\% at matched resolution of 0.65 mm edge-spread-function (ESF) width. Clinical studies confirmed these findings, with variance reduced by ∼15\% in peripheral regions of the head without loss in spatial resolution, improving visual image quality in detection of peridural hemorrhage. A bowtie filter and polyenergetic gain correction improved image uniformity, and early results demonstrated that the proposed PWLS{\^a}- method showed a ∼40\% reduction in variance compared to conventional PWLS when used with a bowtie filter. Conclusion: A more accurate noise model incorporated in PWLS statistical weights to account for fluence modulation and electronic readout noise reduces image noise and improves soft-tissue imaging performance in CBCT for clinical applications requiring a high degree of contrast resolution.",
keywords = "Cone-beam CT, Dual-gain, Fluence modulation, Image noise, Image quality, Model-based image reconstruction",
author = "P. Wu and \{Sisniega Crespo\}, Alejandro and Stayman, \{J. W.\} and W. Zbijewski and D. Foos and X. Wang and Nafi Aygun and R. Stevens and Siewerdsen, \{J. H.\}",
note = "Publisher Copyright: {\textcopyright} SPIE. Downloading of the abstract is permitted for personal use only.; Medical Imaging 2019: Physics of Medical Imaging ; Conference date: 17-02-2019 Through 20-02-2019",
year = "2019",
doi = "10.1117/12.2513417",
language = "English (US)",
series = "Progress in Biomedical Optics and Imaging - Proceedings of SPIE",
publisher = "SPIE",
editor = "Schmidt, \{Taly Gilat\} and Guang-Hong Chen and Hilde Bosmans",
booktitle = "Medical Imaging 2019",
}