T1 - Comparison of the anterior capsulotomy edge created by manual capsulorhexis and 2 femtosecond laser platforms
T2 - Scanning electron microscopy study
AU - Al Harthi, Khaled
AU - Al Shahwan, Sami
AU - Al Towerki, Abdulelah
AU - Banerjee, P. Pat
AU - Behrens, Ashley
AU - Edward, Deepak P.
N1 - Publisher Copyright:
© 2014 ASCRS and ESCRS.
PY - 2014/12/1
Y1 - 2014/12/1
N2 - Purpose To compare the scanning electron microscopy (SEM) features of the anterior capsule edge created by continuous curvilinear capsulorhexis (CCC) and femtosecond laser-assisted capsulotomy using angular second moment and contrast. Setting King Khaled Eye Specialist Hospital, Riyadh, Kingdom of Saudi Arabia. Design Prospective comparative series. Methods Anterior capsule specimens following CCC (n = 10) or femtosecond laser-assisted capsulotomy using 2 platforms (Lensx, n = 9, and Victus, n = 10) were studied by SEM. Irregularity of the capsule edge was quantified using 2 parameters (angular second moment and contrast) using ImageJ software. The clinical features and laser parameters were correlated with angular second moment and contrast. Results By SEM, the femtosecond laser-assisted capsulotomy edge surfaces created by both lasers showed marked irregularity compared with the smooth edge of the CCC. The angular second moment and contrast measures for both lasers differed significantly from those obtained for CCC (P<.001). There was no between-laser difference in angular second moment and contrast measures. The angular second moment showed only a weak negative correlation with increasing laser power, whereas contrast showed a weak positive correlation with increasing power. Conclusions Both laser platforms created an irregular capsulotomy edge. The angular second moment and contrast quantified capsule edge irregularities for further comparisons. These measures could be used to quantify efforts to reduce capsule-edge irregularity from femtosecond laser-lens capsule interaction. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
AB - Purpose To compare the scanning electron microscopy (SEM) features of the anterior capsule edge created by continuous curvilinear capsulorhexis (CCC) and femtosecond laser-assisted capsulotomy using angular second moment and contrast. Setting King Khaled Eye Specialist Hospital, Riyadh, Kingdom of Saudi Arabia. Design Prospective comparative series. Methods Anterior capsule specimens following CCC (n = 10) or femtosecond laser-assisted capsulotomy using 2 platforms (Lensx, n = 9, and Victus, n = 10) were studied by SEM. Irregularity of the capsule edge was quantified using 2 parameters (angular second moment and contrast) using ImageJ software. The clinical features and laser parameters were correlated with angular second moment and contrast. Results By SEM, the femtosecond laser-assisted capsulotomy edge surfaces created by both lasers showed marked irregularity compared with the smooth edge of the CCC. The angular second moment and contrast measures for both lasers differed significantly from those obtained for CCC (P<.001). There was no between-laser difference in angular second moment and contrast measures. The angular second moment showed only a weak negative correlation with increasing laser power, whereas contrast showed a weak positive correlation with increasing power. Conclusions Both laser platforms created an irregular capsulotomy edge. The angular second moment and contrast quantified capsule edge irregularities for further comparisons. These measures could be used to quantify efforts to reduce capsule-edge irregularity from femtosecond laser-lens capsule interaction. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
UR - http://www.scopus.com/inward/record.url?scp=84926143931&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84926143931&partnerID=8YFLogxK
U2 - 10.1016/j.jcrs.2014.10.001
DO - 10.1016/j.jcrs.2014.10.001
M3 - Article
C2 - 25450245
AN - SCOPUS:84926143931
SN - 0886-3350
VL - 40
SP - 2106
EP - 2112
JO - Journal of cataract and refractive surgery
JF - Journal of cataract and refractive surgery
IS - 12
ER -