T1 - Comparison of simultaneous prism and cover test (SPCT) and prism and alternate cover test (PACT) measurements with final power of Press-On prism power dispensed
AU - Christoff, Alex
N1 - Publisher Copyright:
© 2024 American Association for Pediatric Ophthalmology and Strabismus
PY - 2024/6
Y1 - 2024/6
N2 - Purpose: To investigate the association of strabismic angle obtained by simultaneous prism and cover test (SPCT) and prism alternate cover test (PACT) with the final power of Press-On prism used in adults with symptomatic strabismus. Methods: The medical records of consecutive patients seen by a single orthoptist at an urban, tertiary care hospital over a 36-month period were reviewed retrospectively. All subjects had been prescribed Press-On prism for diplopia after evaluation with SPCT and PACT measurements at distance fixation. Prism dispensed was chosen by the patient using a trial Press-On prism set. Results: A total of 244 charts were reviewed. Of these, 108 adult patients had prism dispensed, and 32 had both SPCT and PACT measurements. Mean SPCT measurement was 7Δ (median, 6Δ; range, 3Δ-14Δ); mean PACT, 13Δ (median, 11Δ; range, 8Δ-20Δ). The mean prism power dispensed was 7Δ (median, 6Δ; range, 1Δ-15Δ); this was not significantly different from mean SPCT (P = 0.35). There was a large difference (6Δ) between mean PACT measurements and mean prism dispensed (P < 0.001). At follow-up of 1 year, 21 patients (66%) remained in prism. Nine patients (4%) elected to undergo eye muscle surgery, 7 with horizontal strabismus, 6 of whom had SPCT measurements of >10Δ and PACT measurements of >15Δ. Conclusions: Press-On prism power used was more closely tied to the angle of strabismus obtained by SPCT. Overall success rate of Press-On prism was good when the prism power dispensed was close to the SPCT measurement, suggesting that it is reasonable to initiate treatment with a weaker prism, approximating the SPCT measurement, building up only if there are continuing symptoms.
AB - Purpose: To investigate the association of strabismic angle obtained by simultaneous prism and cover test (SPCT) and prism alternate cover test (PACT) with the final power of Press-On prism used in adults with symptomatic strabismus. Methods: The medical records of consecutive patients seen by a single orthoptist at an urban, tertiary care hospital over a 36-month period were reviewed retrospectively. All subjects had been prescribed Press-On prism for diplopia after evaluation with SPCT and PACT measurements at distance fixation. Prism dispensed was chosen by the patient using a trial Press-On prism set. Results: A total of 244 charts were reviewed. Of these, 108 adult patients had prism dispensed, and 32 had both SPCT and PACT measurements. Mean SPCT measurement was 7Δ (median, 6Δ; range, 3Δ-14Δ); mean PACT, 13Δ (median, 11Δ; range, 8Δ-20Δ). The mean prism power dispensed was 7Δ (median, 6Δ; range, 1Δ-15Δ); this was not significantly different from mean SPCT (P = 0.35). There was a large difference (6Δ) between mean PACT measurements and mean prism dispensed (P < 0.001). At follow-up of 1 year, 21 patients (66%) remained in prism. Nine patients (4%) elected to undergo eye muscle surgery, 7 with horizontal strabismus, 6 of whom had SPCT measurements of >10Δ and PACT measurements of >15Δ. Conclusions: Press-On prism power used was more closely tied to the angle of strabismus obtained by SPCT. Overall success rate of Press-On prism was good when the prism power dispensed was close to the SPCT measurement, suggesting that it is reasonable to initiate treatment with a weaker prism, approximating the SPCT measurement, building up only if there are continuing symptoms.
UR - http://www.scopus.com/inward/record.url?scp=85191416012&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85191416012&partnerID=8YFLogxK
U2 - 10.1016/j.jaapos.2024.103918
DO - 10.1016/j.jaapos.2024.103918
M3 - Article
C2 - 38593867
AN - SCOPUS:85191416012
SN - 1091-8531
VL - 28
JO - Journal of AAPOS
JF - Journal of AAPOS
IS - 3
M1 - 103918
ER -