TY - GEN
T1 - Comparison of integrated radiation transport models with TEPC measurements for the average quality factors in space flights
AU - Kim, Myung Hee Y.
AU - Nikjoo, Hooshang
AU - Dicello, John F.
AU - Pisacane, Vincent L.
AU - Cucinotta, Francis A.
PY - 2007
Y1 - 2007
N2 - The purpose of this work was to test our theoretical model for the interpretation of radiation data measured in space. During the space missions astronauts are exposed to the complex field of radiation type and kinetic energies from galactic cosmic rays (GCRs), trapped protons, and sometimes solar particle events (SPEs). The tissue equivalent proportional counter (TEPC) is a simple, time-dependent approach to radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Qavg(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Qavg(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y, deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. Using an integrated space radiation model (which includes the transport codes BRYNTRN and HZETRN, and the quantum nuclear interaction model QMSFRG) and the response distribution functions of the walled-TEPC, we compared model calculations with the walled-TEPC measurements from NASA missions in LEO in order to develop a method of accurate exposure predictions for the lunar and the Mars missions. Good agreement was found for Qavg(y) between the model and measured spectra from past NASA missions. The Qavg(y) values for the trapped or the solar protons over-estimate the Q avg(LET) values, and the quantities increase with shield thickness due to nuclear fragmentation. The Qavg(y) for the complete GCR spectra measured from flight TEPCs under-estimate the Qavg(LET). The values for the GCR decrease with the shield thickness. Our analysis for a proper interpretation of observed data supports the use of TEPCs for monitoring the space radiation environment.
AB - The purpose of this work was to test our theoretical model for the interpretation of radiation data measured in space. During the space missions astronauts are exposed to the complex field of radiation type and kinetic energies from galactic cosmic rays (GCRs), trapped protons, and sometimes solar particle events (SPEs). The tissue equivalent proportional counter (TEPC) is a simple, time-dependent approach to radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Qavg(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Qavg(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y, deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. Using an integrated space radiation model (which includes the transport codes BRYNTRN and HZETRN, and the quantum nuclear interaction model QMSFRG) and the response distribution functions of the walled-TEPC, we compared model calculations with the walled-TEPC measurements from NASA missions in LEO in order to develop a method of accurate exposure predictions for the lunar and the Mars missions. Good agreement was found for Qavg(y) between the model and measured spectra from past NASA missions. The Qavg(y) values for the trapped or the solar protons over-estimate the Q avg(LET) values, and the quantities increase with shield thickness due to nuclear fragmentation. The Qavg(y) for the complete GCR spectra measured from flight TEPCs under-estimate the Qavg(LET). The values for the GCR decrease with the shield thickness. Our analysis for a proper interpretation of observed data supports the use of TEPCs for monitoring the space radiation environment.
UR - http://www.scopus.com/inward/record.url?scp=48349140088&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=48349140088&partnerID=8YFLogxK
U2 - 10.1109/NSSMIC.2007.4436619
DO - 10.1109/NSSMIC.2007.4436619
M3 - Conference contribution
AN - SCOPUS:48349140088
SN - 1424409233
SN - 9781424409235
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 2362
EP - 2367
BT - 2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC
T2 - 2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC
Y2 - 27 October 2007 through 3 November 2007
ER -