TY - JOUR
T1 - Comparing Ultra-hypofractionated Proton versus Photon Therapy in Extremity Soft Tissue Sarcoma
AU - Thomas, Rehema
AU - Chen, Hao
AU - Gogineni, Emile
AU - Halthore, Aditya
AU - Floreza, Bethlehem
AU - Esho-Voltaire, Temiloluwa
AU - Weaver, Arcelia
AU - Alcorn, Sara
AU - Ladra, Matthew
AU - Li, Heng
AU - Deville, Curtiland
N1 - Publisher Copyright:
Copyright © 2022 The Author(s)
PY - 2023
Y1 - 2023
N2 - Purpose: Recent single institution, phase II evidence has demonstrated the feasibility and efficacy of ultra-hypofractionated, preoperative photon therapy in 5 fractions for the treatment of soft tissue sarcoma (STS). Our purpose was to evaluate the dosimetric benefits of modern scanning beam proton therapy compared with conventional photon radiation therapy (RT) for the neoadjuvant treatment of adult extremity STS. Materials and Methods: Existing proton and photon plans for 11 adult patients with STS of the lower extremities previously treated preoperatively with neoadjuvant RT at our center were used to create proton therapy plans using Raystation Treatment Planning System v10.A. Volumes were delineated, and doses reported consistent with International Commission on Radiation Units and Measurements reports 50, 62, and 78. Target volumes were optimized such that 100% clinical target volume (CTV) was covered by 99% of the prescription dose. The prescribed dose was 30 Gy for PT and RT delivered in 5 fractions. For proton therapy, doses are reported in GyRBE = 1.1 Gy. The constraints for adjacent organs at risk (OARs) within 1 cm of the CTV were the following: femur V30Gy ≤ 50%, joint V30Gy < 50%, femoral head V30Gy ≤ 5 cm3, strip V12 ≤ 10%, and skin V12 < 50%. Target coverage goals, OAR constraints, and integral dose were compared by Student t test with P < .05 significance. Results: A minimum 99% CTV coverage was achieved for all plans. OAR dose constraints were achieved for all proton and photon plans; however, mean doses to the femur (10.7 ± 8.5 vs 16.1 ± 7.7 GyRBE), femoral head (2.0 ± 4.4 vs 3.6 ± 6.4 GyRBE), and proximal joint (1.8 ± 2.4 vs 3.5 ± 4.4 GyRBE) were all significantly lower with PT vs intensity-modulated radiation therapy (IMRT) (all P < .05). Integral dose was significantly reduced for proton vs photon plans. Conformity and heterogeneity indices were significantly better for proton therapy. Conclusion: Proton therapy maintained target coverage while significantly reducing integral and mean doses to the proximal organs at risk compared with RT. Further prospective investigation is warranted to validate these findings and potential benefit in the management of adult STS.
AB - Purpose: Recent single institution, phase II evidence has demonstrated the feasibility and efficacy of ultra-hypofractionated, preoperative photon therapy in 5 fractions for the treatment of soft tissue sarcoma (STS). Our purpose was to evaluate the dosimetric benefits of modern scanning beam proton therapy compared with conventional photon radiation therapy (RT) for the neoadjuvant treatment of adult extremity STS. Materials and Methods: Existing proton and photon plans for 11 adult patients with STS of the lower extremities previously treated preoperatively with neoadjuvant RT at our center were used to create proton therapy plans using Raystation Treatment Planning System v10.A. Volumes were delineated, and doses reported consistent with International Commission on Radiation Units and Measurements reports 50, 62, and 78. Target volumes were optimized such that 100% clinical target volume (CTV) was covered by 99% of the prescription dose. The prescribed dose was 30 Gy for PT and RT delivered in 5 fractions. For proton therapy, doses are reported in GyRBE = 1.1 Gy. The constraints for adjacent organs at risk (OARs) within 1 cm of the CTV were the following: femur V30Gy ≤ 50%, joint V30Gy < 50%, femoral head V30Gy ≤ 5 cm3, strip V12 ≤ 10%, and skin V12 < 50%. Target coverage goals, OAR constraints, and integral dose were compared by Student t test with P < .05 significance. Results: A minimum 99% CTV coverage was achieved for all plans. OAR dose constraints were achieved for all proton and photon plans; however, mean doses to the femur (10.7 ± 8.5 vs 16.1 ± 7.7 GyRBE), femoral head (2.0 ± 4.4 vs 3.6 ± 6.4 GyRBE), and proximal joint (1.8 ± 2.4 vs 3.5 ± 4.4 GyRBE) were all significantly lower with PT vs intensity-modulated radiation therapy (IMRT) (all P < .05). Integral dose was significantly reduced for proton vs photon plans. Conformity and heterogeneity indices were significantly better for proton therapy. Conclusion: Proton therapy maintained target coverage while significantly reducing integral and mean doses to the proximal organs at risk compared with RT. Further prospective investigation is warranted to validate these findings and potential benefit in the management of adult STS.
KW - hypofractionation
KW - neoadjuvant radiation
KW - preoperative radiation
KW - proton therapy
KW - soft tissue sarcoma
KW - stereotactic body proton therapy
KW - stereotactic body radiation therapy
KW - ultra-hypofractionation
UR - http://www.scopus.com/inward/record.url?scp=85171186034&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85171186034&partnerID=8YFLogxK
U2 - 10.14338/IJPT-22-00022.1
DO - 10.14338/IJPT-22-00022.1
M3 - Article
C2 - 36721484
AN - SCOPUS:85171186034
SN - 2331-5180
VL - 9
SP - 30
EP - 39
JO - International Journal of Particle Therapy
JF - International Journal of Particle Therapy
IS - 3
ER -