TY - JOUR
T1 - Comparative safety and effectiveness of midline catheters vs. peripherally inserted central catheters
T2 - a systematic review and meta-analysis
AU - Aljameie, Mohammed
AU - Ahmed Shimal, Aya
AU - Mahmoud, Mohamed H.
AU - Abbas, Omar F.
AU - Oudah, Alaa Mohammed
AU - Ahmed, Marafi Jammaa
AU - Hamzah, Khadeeja Ali
AU - Mansour, Anas
AU - Abdullatif Abdulqader, Wael
AU - Aljubori, Eathar
AU - Mohammed, Ghadeer
AU - Alkhateeb, Fayez Salahedin
AU - El-Ramly, Toka Aziz
AU - Al-Sagban, Alhareth
AU - Graham, Howard
AU - Musri, Maria Carolina
N1 - Publisher Copyright:
© 2026 Aljameie, Ahmed Shimal, Mahmoud, Abbas, Oudah, Ahmed, Hamzah, Mansour, Abdullatif Abdulqader, Aljubori, Mohammed, Alkhateeb, El-Ramly, Al-Sagban, Graham and Musri.
PY - 2026
Y1 - 2026
N2 - Background & objective – Peripherally inserted central catheters (PICCs) and midline catheters (MCs) are widely used for intravenous therapy, but their relative safety and effectiveness remain uncertain. This systematic review and meta-analysis aimed to compare complication rates between PICCs and MCs. Methods – We systematically searched PubMed, Scopus, Embase, and Web of Science for randomized controlled trials (RCTs) and observational studies evaluating PICCs vs. MCs. Risk of bias was assessed using the Cochrane RoB 2 tool for RCTs and the Newcastle-Ottawa Scale for observational studies. Meta-analyses were performed to calculate pooled risk ratios (RRs) and standardized mean differences (SMDs) with 95% confidence intervals (CIs). Results – Fifteen studies (3 RCTs and 12 cohort studies) including over 27, 000 patients were analyzed. PICCs were associated with a significantly higher risk of CRBSIs compared with MCs (RR = 4.18, 95% CI: 2.87–6.08; p < 0.01). No significant differences were observed between the two devices in rates of deep vein thrombosis (DVT), pulmonary embolism (PE), device failure, occlusion, dislodgement, catheter migration, phlebitis, or mortality. PICCs demonstrated longer dwell times (SMD = 0.68; 95% CI: 0.18–1.07; p < 0.01), consistent with their use in prolonged therapies. Conclusion – MCs are associated with a lower risk of bloodstream infections compared with PICCs. PICCs remain appropriate for long-term therapy, while MCs may represent a safer alternative for shorter courses. Device selection should be individualized based on patient risk factors, treatment duration, and clinical context.
AB - Background & objective – Peripherally inserted central catheters (PICCs) and midline catheters (MCs) are widely used for intravenous therapy, but their relative safety and effectiveness remain uncertain. This systematic review and meta-analysis aimed to compare complication rates between PICCs and MCs. Methods – We systematically searched PubMed, Scopus, Embase, and Web of Science for randomized controlled trials (RCTs) and observational studies evaluating PICCs vs. MCs. Risk of bias was assessed using the Cochrane RoB 2 tool for RCTs and the Newcastle-Ottawa Scale for observational studies. Meta-analyses were performed to calculate pooled risk ratios (RRs) and standardized mean differences (SMDs) with 95% confidence intervals (CIs). Results – Fifteen studies (3 RCTs and 12 cohort studies) including over 27, 000 patients were analyzed. PICCs were associated with a significantly higher risk of CRBSIs compared with MCs (RR = 4.18, 95% CI: 2.87–6.08; p < 0.01). No significant differences were observed between the two devices in rates of deep vein thrombosis (DVT), pulmonary embolism (PE), device failure, occlusion, dislodgement, catheter migration, phlebitis, or mortality. PICCs demonstrated longer dwell times (SMD = 0.68; 95% CI: 0.18–1.07; p < 0.01), consistent with their use in prolonged therapies. Conclusion – MCs are associated with a lower risk of bloodstream infections compared with PICCs. PICCs remain appropriate for long-term therapy, while MCs may represent a safer alternative for shorter courses. Device selection should be individualized based on patient risk factors, treatment duration, and clinical context.
KW - complications
KW - meta-analysis
KW - midline catheter (MC)
KW - PICC catheter
KW - safety
UR - https://www.scopus.com/pages/publications/105047590764
UR - https://www.scopus.com/pages/publications/105047590764#tab=citedBy
U2 - 10.3389/fcvm.2026.1890087
DO - 10.3389/fcvm.2026.1890087
M3 - Article
C2 - 42609201
AN - SCOPUS:105047590764
SN - 2297-055X
VL - 13
JO - Frontiers in Cardiovascular Medicine
JF - Frontiers in Cardiovascular Medicine
M1 - 1890087
ER -