TY - JOUR
T1 - Coherence Metrics for Reader-Independent Differentiation of Cystic From Solid Breast Masses in Ultrasound Images
AU - Wiacek, Alycen
AU - Oluyemi, Eniola
AU - Myers, Kelly
AU - Ambinder, Emily
AU - Bell, Muyinatu A.Lediju
N1 - Funding Information:
Funding for this research was provided by the Oak Ridge Associated Universities (ORAU) Ralph E. Powe Junior Faculty Enhancement Award and the National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health under Award No. R01EB032960 (both awarded to M.A.L.B.). A.W. is a recipient of the 2021–2022 Achievement Rewards for College Scientists (ARCS) Foundation Scholarship and the 2022 Siebel Scholarship.
Publisher Copyright:
© 2022 The Authors
PY - 2023/1
Y1 - 2023/1
N2 - Traditional breast ultrasound imaging is a low-cost, real-time and portable method to assist with breast cancer screening and diagnosis, with particular benefits for patients with dense breast tissue. We previously demonstrated that incorporating coherence-based beamforming additionally improves the distinction of fluid-filled from solid breast masses, based on qualitative image interpretation by board-certified radiologists. However, variable sensitivity (range: 0.71–1.00 when detecting fluid-filled masses) was achieved by the individual radiologist readers. Therefore, we propose two objective coherence metrics, lag-one coherence (LOC) and coherence length (CL), to quantitatively determine the content of breast masses without requiring reader assessment. Data acquired from 31 breast masses were analyzed. Ideal separation (i.e., 1.00 sensitivity and specificity) was achieved between fluid-filled and solid breast masses based on the mean or median LOC value within each mass. When separated based on mean and median CL values, the sensitivity/specificity decreased to 1.00/0.95 and 0.92/0.89, respectively. The greatest sensitivity and specificity were achieved in dense, rather than non-dense, breast tissue. These results support the introduction of an objective, reader-independent method for automated diagnoses of cystic breast masses.
AB - Traditional breast ultrasound imaging is a low-cost, real-time and portable method to assist with breast cancer screening and diagnosis, with particular benefits for patients with dense breast tissue. We previously demonstrated that incorporating coherence-based beamforming additionally improves the distinction of fluid-filled from solid breast masses, based on qualitative image interpretation by board-certified radiologists. However, variable sensitivity (range: 0.71–1.00 when detecting fluid-filled masses) was achieved by the individual radiologist readers. Therefore, we propose two objective coherence metrics, lag-one coherence (LOC) and coherence length (CL), to quantitatively determine the content of breast masses without requiring reader assessment. Data acquired from 31 breast masses were analyzed. Ideal separation (i.e., 1.00 sensitivity and specificity) was achieved between fluid-filled and solid breast masses based on the mean or median LOC value within each mass. When separated based on mean and median CL values, the sensitivity/specificity decreased to 1.00/0.95 and 0.92/0.89, respectively. The greatest sensitivity and specificity were achieved in dense, rather than non-dense, breast tissue. These results support the introduction of an objective, reader-independent method for automated diagnoses of cystic breast masses.
KW - Breast cancer
KW - Breast ultrasound
KW - Coherence-based beamforming
KW - Complicated cysts
UR - http://www.scopus.com/inward/record.url?scp=85141229537&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85141229537&partnerID=8YFLogxK
U2 - 10.1016/j.ultrasmedbio.2022.08.018
DO - 10.1016/j.ultrasmedbio.2022.08.018
M3 - Article
C2 - 36333154
AN - SCOPUS:85141229537
SN - 0301-5629
VL - 49
SP - 256
EP - 268
JO - Ultrasound in Medicine and Biology
JF - Ultrasound in Medicine and Biology
IS - 1
ER -