TY - JOUR
T1 - Clinical outcomes in cranioplasty
T2 - Risk factors and choice of reconstructive material
AU - Reddy, Sashank
AU - Khalifian, Saami
AU - Flores, José M.
AU - Bellamy, Justin
AU - Manson, Paul N.
AU - Rodriguez, Eduardo D.
AU - Dorafshar, Amir H.
PY - 2014/4
Y1 - 2014/4
N2 - BACKGROUND: Continuing advances in cranioplasty have enabled repair of increasingly complicated cranial defects. However, the optimal materials and approaches for particular clinical scenarios remain unclear. This study examines outcomes following cranioplasty for a variety of indications in patients treated with alloplastic material, autogenous tissue, or a combination of both. METHODS: THE AUTHORS CONDUCTED: a retrospective analysis on 180 patients who had 195 cranioplasties performed between 1993 and 2010. RESULTS: Materials used for cranioplasty included alloplastic for 42.6 percent (83 of 195), autologous for 19.0 percent (37 of 195), and both combined for 38.5 percent (75 of 195). Mean defect size was 70.5 cm2. A subset of patients had undergone previous irradiation (12.2 percent; 22 of 180) or had preoperative infections (30.6 percent; 55 of 180). The most common complication was postoperative infection (15.9 percent; 31 of 195). Factors that significantly predisposed to complications included preoperative radiation, previous infection, and frontal location. Preoperative radiation was the strongest predictor of having any postoperative complications, with an adjusted odds ratio of 6.91 (p < 0.005). Irradiated patients (OR, 7.96; p < 0.05) and patients undergoing frontal cranioplasties (OR, 2.83; p < 0.05) were more likely to require repeated operation. Preoperative infection predisposed patients to exposure of hardware in alloplastic reconstructions (OR, 3.13; p < 0.05). CONCLUSIONS: Despite the evolution of cranioplasty techniques and materials, complications are not uncommon. The choice of reconstructive material may modify the risk of developing postoperative complications but appears less important than the clinical history in affecting outcome.
AB - BACKGROUND: Continuing advances in cranioplasty have enabled repair of increasingly complicated cranial defects. However, the optimal materials and approaches for particular clinical scenarios remain unclear. This study examines outcomes following cranioplasty for a variety of indications in patients treated with alloplastic material, autogenous tissue, or a combination of both. METHODS: THE AUTHORS CONDUCTED: a retrospective analysis on 180 patients who had 195 cranioplasties performed between 1993 and 2010. RESULTS: Materials used for cranioplasty included alloplastic for 42.6 percent (83 of 195), autologous for 19.0 percent (37 of 195), and both combined for 38.5 percent (75 of 195). Mean defect size was 70.5 cm2. A subset of patients had undergone previous irradiation (12.2 percent; 22 of 180) or had preoperative infections (30.6 percent; 55 of 180). The most common complication was postoperative infection (15.9 percent; 31 of 195). Factors that significantly predisposed to complications included preoperative radiation, previous infection, and frontal location. Preoperative radiation was the strongest predictor of having any postoperative complications, with an adjusted odds ratio of 6.91 (p < 0.005). Irradiated patients (OR, 7.96; p < 0.05) and patients undergoing frontal cranioplasties (OR, 2.83; p < 0.05) were more likely to require repeated operation. Preoperative infection predisposed patients to exposure of hardware in alloplastic reconstructions (OR, 3.13; p < 0.05). CONCLUSIONS: Despite the evolution of cranioplasty techniques and materials, complications are not uncommon. The choice of reconstructive material may modify the risk of developing postoperative complications but appears less important than the clinical history in affecting outcome.
UR - http://www.scopus.com/inward/record.url?scp=84898756884&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84898756884&partnerID=8YFLogxK
U2 - 10.1097/PRS.0000000000000013
DO - 10.1097/PRS.0000000000000013
M3 - Article
C2 - 24675189
AN - SCOPUS:84898756884
SN - 0032-1052
VL - 133
SP - 864
EP - 873
JO - Plastic and reconstructive surgery
JF - Plastic and reconstructive surgery
IS - 4
ER -