TY - JOUR
T1 - Characterization of viable and nonviable myocardium at MR imaging
T2 - Comparison of gadolinium-based extracellular and blood pool contrast materials versus manganese-based contrast materials in a rat myocardial infarction model
AU - Flacke, Sebastian
AU - Allen, John S.
AU - Chia, Jon M.
AU - Wible, James H.
AU - Periasamy, M. Peri
AU - Adams, Max D.
AU - Adzamli, I. Kofi
AU - Lorenz, Christine H.
PY - 2003/3/1
Y1 - 2003/3/1
N2 - PURPOSE: To determine the contrast agent behavior of gadolinium-based (extracellular and albumin-binding) and manganese-based contrast media for late-enhancement imaging of myocardial infarction. MATERIALS AND METHODS: Coronary ligation was performed in 30 rats, and they were serially imaged with segmented inversion-recovery gradient-echo magnetic resonance (MR) imaging (repetition time msec/echo time msec/inversion time msec [fixed], 5.2/2.5/430; flip angle, 15°) during 1 hour after administration of contrast media by using a 1.5-T MR unit. Serial measurements of the longitudinal relaxation were performed by using the Look-Locker approach (repetition time msec/echo time msec, 1,000/3.5; flip angle, 10°). Detection and size of infarction were evaluated at each time point and compared with end-point histologic findings. RESULTS: For all manganese-based media, the contrast agent cleared from the blood pool rapidly. Manganese-based contrast media allowed precise labeling of viable cardiomyocytes within 30 minutes, and the labeling persisted for at least 1 hour. Accumulation of gadoversetamide in the infarct area was apparent after 5 minutes, and the peak contrast-to-noise ratio (CNR) between infarct and myocardium was comparable to the peak CNR of manganese-based contrast agents. Extracellular gadopentetate dimeglumine provided excellent infarct detection but a small imaging window for precise sizing of the infarct if a fixed inversion time of 430 msec was used. Albumin-binding gadolinium-based contrast media provided a longer imaging window, but infarct size was overestimated because of the nonspecific distribution of the unbound gadolinium agent. CONCLUSION: When extracellular gadolinium-based agents are used for infarct size measurement, imaging parameters and timing are important because the kinetics of both normal and irreversibly injured myocardium must be considered. Manganese-based agents are highly specific and less sensitive to timing for infarct size determination, but further studies are required to determine if they are feasible for human use.
AB - PURPOSE: To determine the contrast agent behavior of gadolinium-based (extracellular and albumin-binding) and manganese-based contrast media for late-enhancement imaging of myocardial infarction. MATERIALS AND METHODS: Coronary ligation was performed in 30 rats, and they were serially imaged with segmented inversion-recovery gradient-echo magnetic resonance (MR) imaging (repetition time msec/echo time msec/inversion time msec [fixed], 5.2/2.5/430; flip angle, 15°) during 1 hour after administration of contrast media by using a 1.5-T MR unit. Serial measurements of the longitudinal relaxation were performed by using the Look-Locker approach (repetition time msec/echo time msec, 1,000/3.5; flip angle, 10°). Detection and size of infarction were evaluated at each time point and compared with end-point histologic findings. RESULTS: For all manganese-based media, the contrast agent cleared from the blood pool rapidly. Manganese-based contrast media allowed precise labeling of viable cardiomyocytes within 30 minutes, and the labeling persisted for at least 1 hour. Accumulation of gadoversetamide in the infarct area was apparent after 5 minutes, and the peak contrast-to-noise ratio (CNR) between infarct and myocardium was comparable to the peak CNR of manganese-based contrast agents. Extracellular gadopentetate dimeglumine provided excellent infarct detection but a small imaging window for precise sizing of the infarct if a fixed inversion time of 430 msec was used. Albumin-binding gadolinium-based contrast media provided a longer imaging window, but infarct size was overestimated because of the nonspecific distribution of the unbound gadolinium agent. CONCLUSION: When extracellular gadolinium-based agents are used for infarct size measurement, imaging parameters and timing are important because the kinetics of both normal and irreversibly injured myocardium must be considered. Manganese-based agents are highly specific and less sensitive to timing for infarct size determination, but further studies are required to determine if they are feasible for human use.
KW - Contrast media, comparative studies
KW - Contrast media, experimental studies
KW - Magnetic resonance (MR), contrast media
KW - Manganese
KW - Myocardium, infarction
UR - http://www.scopus.com/inward/record.url?scp=0037370056&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0037370056&partnerID=8YFLogxK
U2 - 10.1148/radiol.2263020151
DO - 10.1148/radiol.2263020151
M3 - Article
C2 - 12601183
AN - SCOPUS:0037370056
SN - 0033-8419
VL - 226
SP - 731
EP - 738
JO - Radiology
JF - Radiology
IS - 3
ER -