Cardiac magnetic resonance haemodynamics in paediatric heart transplant patients: fick oximetry versus cardiac magnetic resonance phase contrast

Jennifer Schramm, Ileen Cronin, Robert McCarter, Jason G. Mandell, Tacy Downing, Joshua Kanter, Russell Cross, Laura Olivieri

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Lifetime radiation exposure for paediatric orthotopic heart transplant (OHT) patients is significant with cardiac catheterisation as the dominant source. Interventional cardiac magnetic resonance is utilised to obtain simultaneous, radiation-free haemodynamics and flow/function measurements. We sought to compare invasive haemodynamic measurements and radiation exposure in traditional cardiac catheterisation, to comprehensive interventional cardiac magnetic resonance. Methods: Twenty-eight OHT patients who underwent 67 interventional cardiac magnetic resonance procedures at Children’s National Hospital were identified. Both invasive oximetry with peripheral oxygen saturation (Fick) and cardiac magnetic resonance phase contrast measurements of pulmonary and systemic blood flow were performed. Systemic and pulmonary blood flow from the two modalities was compared using Bland–Altman, concordance analysis, and inter-reader correlation. A mixed model was implemented to account for confounding variables and repeat encounters. Radiation dosage data were collected for a contemporaneous cohort of orthotopic heart transplant patients undergoing standard, X-ray-guided catheterisation. Results: Simultaneous cardiac magnetic resonance and Fick have poor agreement in our study based on Lin’s correlation coefficient of 0.68 and 0.73 for pulmonary and systemic blood flow, respectively. Bland–Altman analysis demonstrated a consistent over estimation of cardiac magnetic resonance cardiac output by Fick. The average indexed dose area product for patients undergoing haemodynamics with endomyocardial biopsy was 0.73 (SD ±0.6) Gy*m2/kg. With coronary angiography added, the indexed dose area product was 14.6 (SD ± 7.8) Gy*m2/kg. Conclusions: Cardiac magnetic resonancemeasurements of cardiac output/index in paediatric orthotopic heart transplant patients have poor concordance with Fick estimates; however, cardiac magnetic resonance has good internal validity and inter-reader reliability. Radiation doses are small for haemodynamics with biopsy and increase exponentially with angiography, identifying a new target for cardiac magnetic resonance imaging.

Original languageEnglish (US)
Pages (from-to)262-267
Number of pages6
JournalCardiology in the young
Volume34
Issue number2
DOIs
StatePublished - Feb 15 2024

Keywords

  • Interventional cardiac magnetic resonance
  • pediatric heart transplantation
  • radiation safety

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Pediatrics, Perinatology, and Child Health

Fingerprint

Dive into the research topics of 'Cardiac magnetic resonance haemodynamics in paediatric heart transplant patients: fick oximetry versus cardiac magnetic resonance phase contrast'. Together they form a unique fingerprint.

Cite this