Bicuspid aortic valve with raphe mimicking tricuspid valve

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

Imaging description Bicuspid aortic valves are congenital malformations of the aortic valve that result in two functional aortic valve leaflets. In the majority of cases, the right and left aortic cusps are fused with a central raphe, or ridge, that is variable in size. On static images of the aortic valve acquired in diastole with either cardiac CT or MRI, a bicuspid valve with prominent raphe will have an appearance that mimics a tricuspid valve (Figure 26.1). However, dynamic images obtained during systole will reliably demonstrate the restricted motion of the fused valve and typical fish-mouth appearance of the aortic valve orifice using either modality. Bicuspid valves are also typically morphologically abnormal with leaflet thickening and calcification commonly identified, that can suggest further investigation (Figure 26.2). Fusion occurs between the left and right cusps in the majority of patients. Importance Recognition of a bicuspid valve is important given the increased risk of aortic stenosis, regurgitation, aneurysm, and dissection. Patients with bicuspid valve are closely followed with serial echocardiography to assess valve and ventricular function. Typical clinical scenario Bicuspid aortic valve is the most common congenital cardiovascular abnormality, affecting 1–2% of the population. Bicuspid valve morphology is highly variable; however, fusion of the right and left cusps with a midline raphe is the most common pattern, found in 59% of cases in one large series. Patients with bicuspid valve may be referred to cardiac CT or MRI for assessment of coronary arteries, ventricular function, or aortic size. Bicuspid valves may also be an incidental finding on cardiac imaging exams performed for other indications. Differential diagnosis Tricuspid aortic valve with acquired cusp fusion due to senile degeneration can be difficult to distinguish from congenitally bicuspid aortic valve with raphe given similar morphologies. Central calcification of the midline raphe, unequal cusp size, and the presence of an ascending aortic aneurysm are more commonly associated with bicuspid valves and can suggest the diagnosis.

Original languageEnglish (US)
Title of host publicationPearls and Pitfalls in Cardiovascular Imaging
Subtitle of host publicationPseudolesions, Artifacts and Other Difficult Diagnoses
PublisherCambridge University Press
Pages84-86
Number of pages3
ISBN (Electronic)9781139152228
ISBN (Print)9781107023727
DOIs
StatePublished - Jan 1 2015

ASJC Scopus subject areas

  • Medicine(all)

Fingerprint

Dive into the research topics of 'Bicuspid aortic valve with raphe mimicking tricuspid valve'. Together they form a unique fingerprint.

Cite this