TY - JOUR
T1 - Automated image acquisition and processing using a new generation of 4K × 4K CCD cameras for cryo electron microscopic studies of macromolecular assemblies
AU - Zhang, Peijun
AU - Borgnia, Mario J.
AU - Mooney, Paul
AU - Shi, Dan
AU - Pan, Ming
AU - O'Herron, Philip
AU - Mao, Albert
AU - Brogan, David
AU - Milne, Jacqueline L S
AU - Subramaniam, Sriram
PY - 2003/8/1
Y1 - 2003/8/1
N2 - We have previously reported the development of AutoEM, a software package for semi-automated acquisition of data from a transmission electron microscope. In continuing efforts to improve the speed of structure determination of macromolecular assemblies by electron microscopy, we report here on the performance of a new generation of 4K CCD cameras for use in cryo electron microscopic applications. We demonstrate that at 120kV, and at a nominal magnification of 67000×, power spectra and signal-to-noise ratios for the new 4K CCD camera are comparable to values obtained for film images scanned using a Zeiss scanner to resolutions as high as ∼1/6.5Å-1. The specimen area imaged for each exposure on the 4K CCD is about one-third of the area that can be recorded with a similar exposure on film. The CCD camera also serves the purpose of recording images at low magnification from the center of the hole to measure the thickness of vitrified ice in the hole. The performance of the camera is satisfactory under the low-dose conditions used in cryo electron microscopy, as demonstrated here by the determination of a three-dimensional map at 15Å for the catalytic core of the 1.8MDa Bacillus stearothermophilus icosahedral pyruvate dehydrogenase complex, and its comparison with the previously reported atomic model for this complex obtained by X-ray crystallography.
AB - We have previously reported the development of AutoEM, a software package for semi-automated acquisition of data from a transmission electron microscope. In continuing efforts to improve the speed of structure determination of macromolecular assemblies by electron microscopy, we report here on the performance of a new generation of 4K CCD cameras for use in cryo electron microscopic applications. We demonstrate that at 120kV, and at a nominal magnification of 67000×, power spectra and signal-to-noise ratios for the new 4K CCD camera are comparable to values obtained for film images scanned using a Zeiss scanner to resolutions as high as ∼1/6.5Å-1. The specimen area imaged for each exposure on the 4K CCD is about one-third of the area that can be recorded with a similar exposure on film. The CCD camera also serves the purpose of recording images at low magnification from the center of the hole to measure the thickness of vitrified ice in the hole. The performance of the camera is satisfactory under the low-dose conditions used in cryo electron microscopy, as demonstrated here by the determination of a three-dimensional map at 15Å for the catalytic core of the 1.8MDa Bacillus stearothermophilus icosahedral pyruvate dehydrogenase complex, and its comparison with the previously reported atomic model for this complex obtained by X-ray crystallography.
KW - CCD camera
KW - Cryo electron microscopy
KW - Image processing
UR - http://www.scopus.com/inward/record.url?scp=10744220292&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=10744220292&partnerID=8YFLogxK
U2 - 10.1016/S1047-8477(03)00124-2
DO - 10.1016/S1047-8477(03)00124-2
M3 - Article
C2 - 12972350
AN - SCOPUS:10744220292
SN - 1047-8477
VL - 143
SP - 135
EP - 144
JO - Journal of Structural Biology
JF - Journal of Structural Biology
IS - 2