N2 - This study compares the strength and rigidity of four methods of internal fixation for arthrodesis of the first metatarsophalangeal joint. Ten matched pairs of cadaveric first rays were harvested and arthrodesis performed by one of four techniques: (1) planar excision of joint surfaces and fixation with crossed Kirschner wires, (2) planar excision of joint surfaces and internal fixation with a dorsal plate and screws, (3) planar excision of joint surfaces and internal fixation with an interfragmentary screw, or (4) excision of the joint surfaces using powered conical reamers and fixation with an interfragmentary lag screw. Biomechanical testing with a Bionix 858 materials testing machine was carried out, applying a plantar force utilizing principles of cantilever loading. Force applied and displacement of the arthrodesis were recorded. Of the four methods tested, bony preparation with power conical reamers and supplementary interfragmentary screw fixation was the most stable.
AB - This study compares the strength and rigidity of four methods of internal fixation for arthrodesis of the first metatarsophalangeal joint. Ten matched pairs of cadaveric first rays were harvested and arthrodesis performed by one of four techniques: (1) planar excision of joint surfaces and fixation with crossed Kirschner wires, (2) planar excision of joint surfaces and internal fixation with a dorsal plate and screws, (3) planar excision of joint surfaces and internal fixation with an interfragmentary screw, or (4) excision of the joint surfaces using powered conical reamers and fixation with an interfragmentary lag screw. Biomechanical testing with a Bionix 858 materials testing machine was carried out, applying a plantar force utilizing principles of cantilever loading. Force applied and displacement of the arthrodesis were recorded. Of the four methods tested, bony preparation with power conical reamers and supplementary interfragmentary screw fixation was the most stable.
UR - http://www.scopus.com/inward/record.url?scp=0027228529&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0027228529&partnerID=8YFLogxK
U2 - 10.1177/107110079301400705
DO - 10.1177/107110079301400705
M3 - Article
C2 - 8406259
AN - SCOPUS:0027228529
SN - 1071-1007
VL - 14
SP - 395
EP - 399
JO - Foot and Ankle International
JF - Foot and Ankle International
IS - 7
ER -