TY - JOUR
T1 - Analysis of Agreement of Retinal-Layer Thickness Measures Derived from the Segmentation of Horizontal and Vertical Spectralis OCT Macular Scans
AU - Gonzalez Caldito, Natalia
AU - Antony, Bhavna
AU - He, Yufan
AU - Lang, Andrew
AU - Nguyen, James
AU - Rothman, Alissa
AU - Ogbuokiri, Esther
AU - Avornu, Ama
AU - Balcer, Laura
AU - Frohman, Elliot
AU - Frohman, Teresa C.
AU - Bhargava, Pavan
AU - Prince, Jerry
AU - Calabresi, Peter A.
AU - Saidha, Shiv
N1 - Funding Information:
Shiv Saidha has received consulting fees from Medical Logix for the development of CME programs in neurology and served on scientific advisory boards for Biogen-Idec, Genzyme, Genentech, EMD Serono & Novartis. He has received equity compensation for consulting from JuneBrain LLC, a retinal imaging device developer. He receives research support from Genentech Corporation and the National MS Society, and received support from the Race to Erase MS foundation. He serves on the working committee of the International MS Visual System (IMSVISUAL) consortium.
Funding Information:
This study was funded by Race to Erase MS (to S.S.), NIH (5R01NS082347-02 [to PAC and SS]), National MS Society (RG-1606-08768 to SS), and Walters Foundation (to EMF, LJB and PAC).
Funding Information:
This study was funded by Race to Erase MS (to S.S.), NIH (5R01NS082347-02 [to PAC and SS]), National MS Society (RG-1606-08768 to SS), and Walters Foundation (to EMF, LJB and PAC). We gratefully acknowledge Prof. Jerry Prince (Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA) and his team for providing the Segmentation algorithm used in this study. We thank Norah Cowley for helping with the image adjustments. This study was funded by Race to Erase MS (to S.S.), NIH (5R01NS082347-02 [to PAC and SS]), National MS Society (RG-1606-08768 to SS), and Walters Foundation (to EMF, LJB and PAC).
Publisher Copyright:
© 2017 Taylor & Francis Group, LLC.
PY - 2018/3/4
Y1 - 2018/3/4
N2 - Purpose: Optical coherence tomography (OCT) is a reliable method used to quantify discrete layers of the retina. Spectralis OCT is a device used for this purpose. Spectralis OCT macular scan imaging acquisition can be obtained on either the horizontal or vertical plane. The vertical protocol has been proposed as favorable, due to postulated reduction in confound of Henle’s fibers on segmentation-derived metrics. Yet, agreement of the segmentation measures of horizontal and vertical macular scans remains unexplored. Our aim was to determine this agreement. Materials and methods: Horizontal and vertical macular scans on Spectralis OCT were acquired in 20 healthy controls (HCs) and 20 multiple sclerosis (MS) patients. All scans were segmented using Heidelberg software and a Johns Hopkins University (JHU)-developed method. Agreement was analyzed using Bland–Altman analyses and intra-class correlation coefficients (ICCs). Results: Using both segmentation techniques, mean differences (agreement at the cohort level) in the thicknesses of all macular layers derived from both acquisition protocols in MS patients and HCs were narrow (<1 µm), while the limits of agreement (LOA) (agreement at the individual level) were wider. Using JHU segmentation mean differences (and LOA) for the macular retinal nerve fiber layer (RNFL) and ganglion cell layer + inner plexiform layer (GCIP) in MS were 0.21 µm (−1.57–1.99 µm) and −0.36 µm (−1.44–1.37 µm), respectively. Conclusions: OCT segmentation measures of discrete retinal-layer thicknesses derived from both vertical and horizontal protocols on Spectralis OCT agree excellently at the cohort level (narrow mean differences), but only moderately at the individual level (wide LOA). This suggests patients scanned using either protocol should continue to be scanned with the same protocol. However, due to excellent agreement at the cohort level, measures derived from both acquisitions can be pooled for outcome purposes in clinical trials.
AB - Purpose: Optical coherence tomography (OCT) is a reliable method used to quantify discrete layers of the retina. Spectralis OCT is a device used for this purpose. Spectralis OCT macular scan imaging acquisition can be obtained on either the horizontal or vertical plane. The vertical protocol has been proposed as favorable, due to postulated reduction in confound of Henle’s fibers on segmentation-derived metrics. Yet, agreement of the segmentation measures of horizontal and vertical macular scans remains unexplored. Our aim was to determine this agreement. Materials and methods: Horizontal and vertical macular scans on Spectralis OCT were acquired in 20 healthy controls (HCs) and 20 multiple sclerosis (MS) patients. All scans were segmented using Heidelberg software and a Johns Hopkins University (JHU)-developed method. Agreement was analyzed using Bland–Altman analyses and intra-class correlation coefficients (ICCs). Results: Using both segmentation techniques, mean differences (agreement at the cohort level) in the thicknesses of all macular layers derived from both acquisition protocols in MS patients and HCs were narrow (<1 µm), while the limits of agreement (LOA) (agreement at the individual level) were wider. Using JHU segmentation mean differences (and LOA) for the macular retinal nerve fiber layer (RNFL) and ganglion cell layer + inner plexiform layer (GCIP) in MS were 0.21 µm (−1.57–1.99 µm) and −0.36 µm (−1.44–1.37 µm), respectively. Conclusions: OCT segmentation measures of discrete retinal-layer thicknesses derived from both vertical and horizontal protocols on Spectralis OCT agree excellently at the cohort level (narrow mean differences), but only moderately at the individual level (wide LOA). This suggests patients scanned using either protocol should continue to be scanned with the same protocol. However, due to excellent agreement at the cohort level, measures derived from both acquisitions can be pooled for outcome purposes in clinical trials.
KW - Optical coherence tomography (OCT)
KW - analysis of agreement
KW - multiple sclerosis (MS)
KW - retinal layers
KW - segmentation
UR - http://www.scopus.com/inward/record.url?scp=85038083939&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85038083939&partnerID=8YFLogxK
U2 - 10.1080/02713683.2017.1406526
DO - 10.1080/02713683.2017.1406526
M3 - Article
C2 - 29240464
AN - SCOPUS:85038083939
SN - 0271-3683
VL - 43
SP - 415
EP - 423
JO - Current Eye Research
JF - Current Eye Research
IS - 3
ER -