Anaesthesiological support in a cardiac electrophysiology laboratory: A single-centre prospective observational study

Thibaut Trouvé-Buisson, Lionel Arvieux, Damien Bedague, Myriam Casez-Brasseur, Pascal Defaye, Jean François Payen, Pierre Albaladejo

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

BACKGROUND Implantation of cardiovascular implantable electronic devices (CIEDs) has greatly increased during the last decade and anaesthetic management of these patients remains an open question. OBJECTIVE This study describes anaesthetic management and risk factors associated with complications occurring during these procedures. DESIGN A single-centre prospective observational study. SETTING Grenoble University Hospital, France, from May 2010 to October 2010. PATIENTS All patients admitted to the cardiac electrophysiology laboratory were included. INTERVENTION None. MAIN OUTCOME MEASURES Clinical data, anaesthetic and medical characteristics as well as complications (respiratory or cardiovascular) and treatment were recorded by the anaesthetic nurse at the end of each procedure. RESULTS Two hundred and sixty-nine patients were included, 229 (85%) with an American Society of Anaesthesiologists (ASA) status of 3 or 4, 103 (38%) with a New York Heart Association (NYHA) functional class of 3 or 4 and 136 (51%) with a left ventricular ejection fraction of less than 40%. Two hundred and forty-seven (92%) of the patients underwent deep sedation and 12 (8%) general anaesthesia. Seventy-eight (29%) patients had at least one complication, among whom 21 (27%) had at least one considered as severe. Fifty (19%) of the patients had a respiratory complication and 46 (17%) a cardiovascular complication; the latter was more frequently severe (41 vs. 12%; P=0.001). Lead extraction [odds ratio (OR) 13.7, 95% confidence interval (CI) 3.5 to 53.3; P<0.001], NYHA status of 4 (OR 11.8, 95% CI 1.8 to 74.8; P<0.001), implantable cardioverterdefibrillator (ICD) testing by T-wave shock (OR 3.9, 95% CI 1.53 to 10.2; P=0.005) and length of procedure (OR 1.01, 95% CI 1.004 to 1.031; P=0.013) were identified as independent risk factors for cardiovascular complications. CONCLUSION Patients requiring cardiovascular implantable electronic device (CIED) implantation were fragile with a high complication rate and a high rate of severe complications even with anaesthesiological support. These complications, as well as the need for deep sedation or general anaesthesia, clearly justify the involvement of a qualified anaesthesiologist.

Original languageEnglish (US)
Pages (from-to)658-663
Number of pages6
JournalEuropean Journal of Anaesthesiology
Volume30
Issue number11
DOIs
StatePublished - Nov 2013
Externally publishedYes

ASJC Scopus subject areas

  • Anesthesiology and Pain Medicine

Fingerprint

Dive into the research topics of 'Anaesthesiological support in a cardiac electrophysiology laboratory: A single-centre prospective observational study'. Together they form a unique fingerprint.

Cite this