TY - GEN
T1 - Active point out-of-plane ultrasound calibration
AU - Cheng, Alexis
AU - Guo, Xiaoyu
AU - Zhang, Haichong K.
AU - Kang, Hyun Jae
AU - Etienne-Cummings, Ralph
AU - Boctor, Emad M.
N1 - Publisher Copyright:
© 2015 SPIE.
PY - 2015
Y1 - 2015
N2 - Image-guided surgery systems are often used to provide surgeons with informational support. Due to several unique advantages such as ease of use, real-time image acquisition, and no ionizing radiation, ultrasound is a common intraoperative medical imaging modality used in image-guided surgery systems. To perform advanced forms of guidance with ultrasound, such as virtual image overlays or automated robotic actuation, an ultrasound calibration process must be performed. This process recovers the rigid body transformation between a tracked marker attached to the transducer and the ultrasound image. Point-based phantoms are considered to be accurate, but their calibration framework assumes that the point is in the image plane. In this work, we present the use of an active point phantom and a calibration framework that accounts for the elevational uncertainty of the point. Given the lateral and axial position of the point in the ultrasound image, we approximate a circle in the axial-elevational plane with a radius equal to the axial position. The standard approach transforms all of the imaged points to be a single physical point. In our approach, we minimize the distances between the circular subsets of each image, with them ideally intersecting at a single point. We simulated in noiseless and noisy cases, presenting results on out-of-plane estimation errors, calibration estimation errors, and point reconstruction precision. We also performed an experiment using a robot arm as the tracker, resulting in a point reconstruction precision of 0.64mm.
AB - Image-guided surgery systems are often used to provide surgeons with informational support. Due to several unique advantages such as ease of use, real-time image acquisition, and no ionizing radiation, ultrasound is a common intraoperative medical imaging modality used in image-guided surgery systems. To perform advanced forms of guidance with ultrasound, such as virtual image overlays or automated robotic actuation, an ultrasound calibration process must be performed. This process recovers the rigid body transformation between a tracked marker attached to the transducer and the ultrasound image. Point-based phantoms are considered to be accurate, but their calibration framework assumes that the point is in the image plane. In this work, we present the use of an active point phantom and a calibration framework that accounts for the elevational uncertainty of the point. Given the lateral and axial position of the point in the ultrasound image, we approximate a circle in the axial-elevational plane with a radius equal to the axial position. The standard approach transforms all of the imaged points to be a single physical point. In our approach, we minimize the distances between the circular subsets of each image, with them ideally intersecting at a single point. We simulated in noiseless and noisy cases, presenting results on out-of-plane estimation errors, calibration estimation errors, and point reconstruction precision. We also performed an experiment using a robot arm as the tracker, resulting in a point reconstruction precision of 0.64mm.
KW - Active phantom
KW - Out-of-plane estimation
KW - Point segmentation
KW - Ultrasound calibration
UR - http://www.scopus.com/inward/record.url?scp=84938236960&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84938236960&partnerID=8YFLogxK
U2 - 10.1117/12.2081662
DO - 10.1117/12.2081662
M3 - Conference contribution
AN - SCOPUS:84938236960
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2015
A2 - Webster, Robert J.
A2 - Yaniv, Ziv R.
PB - SPIE
T2 - Medical Imaging 2015: Image-Guided Procedures, Robotic Interventions, and Modeling
Y2 - 22 February 2015 through 24 February 2015
ER -