TY - GEN
T1 - Accuracy analysis of image-based respiratory motion estimation and compensation in respiratorygated PET reconstruction
AU - Chen, Si
AU - Tsui, Benjamin M.W.
N1 - Copyright:
Copyright 2010 Elsevier B.V., All rights reserved.
PY - 2008
Y1 - 2008
N2 - Reconstructed images from respiratory-gated frames of positron emission tomography (PET) data can be used to estimate the patient's respiratory motion estimation. The estimated motion can then be incorporated into iterative image reconstruction methods for respiratory motion compensation. The objective of this study is to investigate two factors in the PET images that can affect the accuracy of image-based motion estimation: image noise and artifacts due to attenuation map misregistration. 4D XCAT (formerly known as NCAT) digital phantom and Monte-Carlo methods were employed to simulate realistic F 18-FDG oncological PET data acquisition of two different noise levels. Hot spherical lesions of different sizes, contrasts and locations in the XCAT phantom were used to simulate tumors in PET imaging. Respiratory-gated PET data were then reconstructed using OS-EM methods with attenuation, uniformity and random coincidence compensation. Two kinds of attenuation maps were used: the attenuation map registered with every respiratory-gated PET frame and that averaged over the respiratory cycle. The image registration method with B-Spline non-rigid transform was applied to the above reconstructed images for motion estimation. The estimated motion was then used to warp the reconstructed images to a reference frame for summation. The recovered contrasts of the lesions were compared for the final reconstructed images from two noise levels using different methods. The results show that the artifacts in PET images due to attenuation map misregistration is another significant factor besides image noise which can affect the motion estimation accuracy.
AB - Reconstructed images from respiratory-gated frames of positron emission tomography (PET) data can be used to estimate the patient's respiratory motion estimation. The estimated motion can then be incorporated into iterative image reconstruction methods for respiratory motion compensation. The objective of this study is to investigate two factors in the PET images that can affect the accuracy of image-based motion estimation: image noise and artifacts due to attenuation map misregistration. 4D XCAT (formerly known as NCAT) digital phantom and Monte-Carlo methods were employed to simulate realistic F 18-FDG oncological PET data acquisition of two different noise levels. Hot spherical lesions of different sizes, contrasts and locations in the XCAT phantom were used to simulate tumors in PET imaging. Respiratory-gated PET data were then reconstructed using OS-EM methods with attenuation, uniformity and random coincidence compensation. Two kinds of attenuation maps were used: the attenuation map registered with every respiratory-gated PET frame and that averaged over the respiratory cycle. The image registration method with B-Spline non-rigid transform was applied to the above reconstructed images for motion estimation. The estimated motion was then used to warp the reconstructed images to a reference frame for summation. The recovered contrasts of the lesions were compared for the final reconstructed images from two noise levels using different methods. The results show that the artifacts in PET images due to attenuation map misregistration is another significant factor besides image noise which can affect the motion estimation accuracy.
UR - http://www.scopus.com/inward/record.url?scp=67649204079&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=67649204079&partnerID=8YFLogxK
U2 - 10.1109/NSSMIC.2008.4774232
DO - 10.1109/NSSMIC.2008.4774232
M3 - Conference contribution
AN - SCOPUS:67649204079
SN - 9781424427154
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 4292
EP - 4295
BT - 2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008
T2 - 2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008
Y2 - 19 October 2008 through 25 October 2008
ER -