TY - JOUR
T1 - A use case study on late stent thrombosis for ontology-based temporal reasoning and analysis
AU - Clark, Kim
AU - Sharma, Deepak
AU - Qin, Rui
AU - Chute, Christopher G.
AU - Tao, Cui
N1 - Funding Information:
This research is partially supported the National Library of Medicine of the National Institutes of Health under Award Number R01LM011829. We thank Ms. Donna Ihrke for her help on annotating the files.
Publisher Copyright:
© 2014 Clark et al.; licensee BioMed Central Ltd.
PY - 2014/12/11
Y1 - 2014/12/11
N2 - In this paper, we show how we have applied the Clinical Narrative Temporal Relation Ontology (CNTRO) and its associated temporal reasoning system (the CNTRO Timeline Library) to trend temporal information within medical device adverse event report narratives. 238 narratives documenting occurrences of late stent thrombosis adverse events from the Food and Drug Administration's (FDA) Manufacturing and User Facility Device Experience (MAUDE) database were annotated and evaluated using the CNTRO Timeline Library to identify, order, and calculate the duration of temporal events. The CNTRO Timeline Library had a 95% accuracy in correctly ordering events within the 238 narratives. 41 narratives included an event in which the duration was documented, and the CNTRO Timeline Library had an 80% accuracy in correctly determining these durations. 77 narratives included documentation of a duration between events, and the CNTRO Timeline Library had a 76% accuracy in determining these durations. This paper also includes an example of how this temporal output from the CNTRO ontology can be used to verify recommendations for length of drug administration, and proposes that these same tools could be applied to other medical device adverse event narratives in order to identify currently unknown temporal trends.
AB - In this paper, we show how we have applied the Clinical Narrative Temporal Relation Ontology (CNTRO) and its associated temporal reasoning system (the CNTRO Timeline Library) to trend temporal information within medical device adverse event report narratives. 238 narratives documenting occurrences of late stent thrombosis adverse events from the Food and Drug Administration's (FDA) Manufacturing and User Facility Device Experience (MAUDE) database were annotated and evaluated using the CNTRO Timeline Library to identify, order, and calculate the duration of temporal events. The CNTRO Timeline Library had a 95% accuracy in correctly ordering events within the 238 narratives. 41 narratives included an event in which the duration was documented, and the CNTRO Timeline Library had an 80% accuracy in correctly determining these durations. 77 narratives included documentation of a duration between events, and the CNTRO Timeline Library had a 76% accuracy in determining these durations. This paper also includes an example of how this temporal output from the CNTRO ontology can be used to verify recommendations for length of drug administration, and proposes that these same tools could be applied to other medical device adverse event narratives in order to identify currently unknown temporal trends.
UR - http://www.scopus.com/inward/record.url?scp=84927914740&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84927914740&partnerID=8YFLogxK
U2 - 10.1186/2041-1480-5-49
DO - 10.1186/2041-1480-5-49
M3 - Article
C2 - 25540680
AN - SCOPUS:84927914740
SN - 2041-1480
VL - 5
JO - Journal of Biomedical Semantics
JF - Journal of Biomedical Semantics
IS - 1
M1 - 49
ER -