A single center's experience with pacemaker implantation after the Cox maze procedure for atrial fibrillation

Niv Ad, Sari D. Holmes, Rabia Ali, Graciela Pritchard, Deborah Lamont

Research output: Contribution to journalArticlepeer-review

Abstract

Objective The Cox maze procedure (CM) is safe and effective for all atrial fibrillation (AF) types. A recent randomized trial found alarming rates of pacemaker implantation (PMI) during hospitalization after CM. The purpose of this study was to assess the rate of PMI and its impact on outcomes after CM. Methods Incidence of PMI was captured for all CM patients (2005-2015; N = 739). Data were collected prospectively. Multivariable logistic regression was conducted to determine risk factors for PMI. Propensity score matching was conducted between concomitant CM patients and patients without surgical ablation since 2011. Results Fifty-two patients (7.0%) had in-hospital PMI after CM. Most common primary indication for PMI was sick sinus syndrome (67%), followed by complete heart block (23%) and sinus bradycardia (10%). The only risk factor for in-hospital PMI was type of procedure (P =.020). Patients with multiple valve procedures were at greatest risk (P =.004-.035). STS-defined perioperative outcomes were similar for patients with and without in-hospital PMI. Sinus rhythm off antiarrhythmic drugs were similar by PMI. After propensity score matching (n = 180 per group), in-hospital PMI was similar in CM patients and those without surgical ablation (5% vs 4%, P =.609). Conclusions This study demonstrated lower incidence of PMI after CM procedures than recently reported. When indicated, PMI was not associated with increased short- or long-term morbidity or inferior freedom from atrial arrhythmia. Efforts to increase surgeon training with the CM procedure and postoperative management awareness are warranted to improve rhythm outcome and minimize adverse events and PMI.

Original languageEnglish (US)
Pages (from-to)139-146.e1
JournalJournal of Thoracic and Cardiovascular Surgery
Volume154
Issue number1
DOIs
StatePublished - Jul 2017
Externally publishedYes

Keywords

  • arrhythmia
  • arrhythmia therapy
  • atrial fibrillation
  • pacemaker

ASJC Scopus subject areas

  • Surgery
  • Pulmonary and Respiratory Medicine
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'A single center's experience with pacemaker implantation after the Cox maze procedure for atrial fibrillation'. Together they form a unique fingerprint.

Cite this