Skip to main navigation Skip to search Skip to main content

3-Year Outcomes of the Edwards SAPIEN Transcatheter Heart Valve for Conduit Failure in the Pulmonary Position From the COMPASSION Multicenter Clinical Trial

  • Damien Kenny
  • , John F. Rhodes
  • , Gregory A. Fleming
  • , Saibal Kar
  • , Evan M. Zahn
  • , Julie Vincent
  • , Girish S. Shirali
  • , Jeremy Gorelick
  • , Mark A. Fogel
  • , John T. Fahey
  • , Dennis W. Kim
  • , Vasilis C. Babaliaros
  • , Aimee K. Armstrong
  • , Ziyad M. Hijazi

Research output: Contribution to journalArticlepeer-review

Abstract

Objectives: This study provides the 3-year follow-up results of the COMPASSION (Congenital Multicenter Trial of Pulmonic Valve Regurgitation Studying the SAPIEN Transcatheter Heart Valve) trial. Patients with moderate to severe pulmonary regurgitation and/or right ventricular outflow tract conduit obstruction were implanted with the SAPIEN transcatheter heart valve (THV). Background: Early safety and efficacy of the Edwards SAPIEN THV in the pulmonary position have been established through a multicenter clinical trial. Methods: Eligible patients were included if body weight was >35 kg and in situ conduit diameter was ≥16 and ≤24 mm. Adverse events were adjudicated by an independent clinical events committee. Three-year clinical and echocardiographic outcomes were evaluated in these patients. Results: Fifty-seven of the 63 eligible patients were accounted for at the 3-year follow-up visit from a total of 69 implantations in 81 enrolled patients. THV implantation was indicated for pulmonary stenosis (7.6%), regurgitation (12.7%), or both (79.7%). Twenty-two patients (27.8%) underwent implantation of 26-mm valves, and 47 patients received 23-mm valves. Functional improvement in New York Heart Association functional class was observed in 93.5% of patients. Mean peak conduit gradient decreased from 37.5 ± 25.4 to 17.8 ± 12.4 mm Hg (p < 0.001), and mean right ventricular systolic pressure decreased from 59.6 ± 17.7 to 42.9 ± 13.4 mm Hg (p < 0.001). Pulmonary regurgitation was mild or less in 91.1% of patients. Freedom from all-cause mortality at 3 years was 98.4%. Freedom from reintervention was 93.7% and from endocarditis was 97.1% at 3 years. There were no observed stent fractures. Conclusions: Transcatheter pulmonary valve replacement using the Edwards SAPIEN THV demonstrates excellent valve function and clinical outcomes at 3-year follow-up.

Original languageEnglish (US)
Pages (from-to)1920-1929
Number of pages10
JournalJACC: Cardiovascular Interventions
Volume11
Issue number19
DOIs
StatePublished - Oct 8 2018
Externally publishedYes

Keywords

  • conduit
  • pulmonary valve replacement
  • SAPIEN THV
  • stent
  • TPVR
  • transcatheter

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of '3-Year Outcomes of the Edwards SAPIEN Transcatheter Heart Valve for Conduit Failure in the Pulmonary Position From the COMPASSION Multicenter Clinical Trial'. Together they form a unique fingerprint.

Cite this